What was found
*INTERCOSTAL CORRODED. FS349.00 €“ FS364.00 AT STGR20R IS CORRODED. (C-CHECK) RO 2/05/2020 REMOVED CORROSION ON INTERCOSTAL AT FS349.0 TO FS364.0 STGR20R, ORIGINAL PART THICKNESS = .063",MATERIAL REMOVED = .003",REMAINING THICKNESS = .060", ALLOWABLE BLEND DEPTH IS 10% OR .006", BLEND IS WITHIN LIMITS, CORROSION WAS ON 2 ELEMENTS OF PART, CORROSION ON 2 ELEMENTS NOT ALLOWABLE, RECEIVED REO TO COVER OUT OF LIMITS CONDITION,C/W ALL STEPS 1 THRU 7 OF REO,REF BOMBARDIER REO.