As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
*ANGLE TIE THAT CONNECTS THE FLOOR BEAM TO THE TOP OF THE CENTER BAGGAGE BAY DOOR STRUCTURE AT FS661.00 LH SIDE CORRODED AROUND FASTENERS (MARKED) (C-CHECK) RO 3/6/2020 REMOVED AND REPLACED ANGLE TIE THAT CONNECTS THE FLOOR BEAM TO THE TOP OF THE CENTER BAGGAGE BAY DOOR STRUCTURE AT FS661.00 LH SIDE REF BOMBARDIER DWG AND CRJ900 SRM. COMPLIED WITH TASK CARD .