What was found
PAX DOOR CUTOUT-AREAS OF LIGHT CORROSION ALONG FLOOR SUPPORT ANGLE BETWEEN FS 310.00 AND FS 349.00 LBL 43 (C-CHECK) RO 3/25/2020 CLEANED AND REMOVED SURFACE CONTAMINATIONS. DAMAGE WAS FOUND TO BE CONTAINED WITHIN FASTENERS WITH NO MATERIAL LOSS TO SURROUNDING SUBSTRATE IN PAX DOOR CUTOUT BETWEEN FS 310.00 AND FS 349.00 LBL43. REMOVED AND REPLACED DAMAGED FASTENERS IAW SKYWEST CRJ200 SRM. RESTORED AIRCRAFT FINISHES IAWSKYWEST CRJ200 SRM.