What was found
WHILE WORKING JOB: 915069104 OP:69 MX TRANS #20646015 ADDITIONAL CORROSION FOUND ON LH PRESSURE FLOOR SILL ANGLE SURROUNDING AFT FUEL VENT MANIFOLD FOOT PRINT AT APPROXIMENTLY FS 824 (C-CHECK) RO 4/23/2020 CORROSION ON LH PRESSURE FLOOR SILL ANGLE SURROUNDING AFT FUEL VENT MANIFOLD FOOT PRINT AT F.S. 824.0 APPROX. REPAIRED TO REO COMPLIED WITH SKYWEST TASK CARD (CL600-2D24) STRUCTURAL MAJOR REPAIR COMPLIED WITH SKYWEST 337 FORM. MINOR BLEND REQUIRED THUS NEGLIGIBLE WEIGHT CHANGE.