What was found
D: REMOVED CORROSION AND APPLIED TEMPORARY REPAIR TO SERVICE DOOR BOTTOM PAN REF. BOMBARDIER REO. PERMANENT REPAIR DUE IN 6000 FLT HRS BY TAT 40364.4 C: MCI RA# 39496 NOTE: MX CODE BUILT TO TRACK VISUAL REINSPECTS DUE EVERY 1800 FLT HRS. *** DO NOT CLOSE UNTIL PERMANENT REPAIR *** (C-CHECK) RO 5/16/2020 COMPLIED WITH PERM REPAIR TO SERVICE DOOR BOTTOM PAN BY REPLACEMENT IAW SRM. M-337 ATTACHED. NO WEIGHT CHANGE REQUIRED. REF DRAWING FOR FASTENER CALL OUT