What was found
FLOOR SUPPORT STRUCTURE LOWER FLOOR SUPPORT ANGLE AT THE BOTTOM OF THE SERVICE DOOR CUT-OUT HAS CORROSION (MARKED). C-CHECK RO 9/1/2020. REMOVED CORROSION ON THE FLOOR SUPPORT STRUCTURE LOWER FLOOR SUPPORT ANGLE AT THE BOTTOM OF THE SERVICE DOOR CUT-OUT, REF: CRJ-200 SRM. EVALUATED AND FOUND TO BE IS OUT OF LIMITS REF. CRJ200 SRM. INSTALLED NEW SERVICE DOOR FLOOR SUPPORT ANGLE PART#601R38303-253 PER BOMBARDIER DWG CRJ 200 SRM.