As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FLOOR SUPPORT STRUCTURE GALLEY MOUNT STRUCTURE BETWEEN FS310 TO FS319 AND APPROX. RBL6 (MARKED). C-CHECK RO 9/1/2020. BLENDED CORROSION ON GALLEY MOUNT FLOOR SUPPORT STRUCTURE BETWEEN FS310 TO FS319 AT APPROX RBL6 REF CRJ 200 SRM. PART WAS OUT OF LIMITS PER REF CRJ 200 SRM. REPLACED REF DWG. SEE CONTINUATION CARD FOR MORE DETAILS.