Service difficulty report · Clamp · Cndair CL6002B19

Difficulty date
October 27, 2020
Submitted
October 30, 2020
Operation
Air carrier
Aircraft
N931EV
Make and model
Cndair CL6002B19
Aircraft serial
8015
Aircraft time
28,504 hours, 28,477 cycles
Part
Clamp
Condition
Leaking
Location
Shutoff Valve
Stage of operation
CL
How discovered
O
Nature of condition
J
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

ANTI ICE DUCT WARNING THROUGH FL210. TROUBLESHOT LT FUSELAGE ANTI ICE DUCT WARNING MESSAGE AND FOUND THE RT 14TH STAGE SHUT OFF VALVE FWD MOUNT TO BE SHOOTING AIR DIRECTLY ON TO THE FIRE DETECTION LOOP RETORQUED THE RT 14TH STAGE SHUT OFF VALVE CLAMPS, IN REFERENCE TO AMM. OPERATIONS CHECK AND LEAK CHECK GOOD AT THIS TIME.