Service difficulty report · Reservoir · Cndair CL6002C10

Difficulty date
November 2, 2020
Submitted
November 2, 2020
Operation
Air carrier
Aircraft
N787SK
Make and model
Cndair CL6002C10
Aircraft serial
10288
Aircraft time
30,330 hours, 18,783 cycles
Part
Reservoir
Condition
Failed
Location
Hyd System
Stage of operation
CL
How discovered
O
Nature of condition
J
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

ON CLIMB OUT HYD 3 SYSTEM HIGH TEMP MESSAGE. COMPLIED WITH QRH, MESSAGE CLEARED. WHEN TURNING PUMP 3B ON AGAIN PUMP FAILED. FLIGHT 5416-FILED CLOSED. PLEASE REFERENCE AML 516739. REMOVED AND REPLACED THE NR 3 HYDRAULIC RESERVOIR, PER CRJ 700 AMM WITH A SERVICEABLE UNIT. SERVICED THE NR 3 HYDRAULIC RESERVOIR AND PERFORMED OPERATIONAL CHECK. BLEED SYSTEM NR 3, PER THE CRJ 700 AMM. QUANTITY INDICATION WORKS WITH NO ISSUES. NO LEAKS NOTED AT THIS TIME. ALL ACCESS PANELS OPENED SECURED CLOSED.