What was found
CARGO DOOR AFT TRACK WORN THRU AT UPPER STOP, MARKED. C-CHECK RO 10/29/2020. BLENDED OUT DAMAGE AT CARGO DOOR AFT RACK AND FOUND TO BE OUT OF LIMITS, REF REO. REMOVED AND INSTALLED A NEW CARGO DOOR AFT TRACK, REF DWG CRJ 200 SRM. PERFORMED PRESSURE CHECK, REF CRJ 200 AMM, PRESSURE CHECK GOOD. COMPLIED WITH TASK CARD. SEE CONTINUATION FOR FURTHER DETAILS.