What was found
CORROSION FOUND ON GUSSET AT FS 319.70 AND STRINGER 20R. C-CHECK RO 11/11/2020. CORROSION FOUND TO BE OUT OF LIMITS, PER CRJ700 SRM. REMOVED AND INSTALLED NEW GUSSET AT FS 319 STGR 20R, REF DWG CRJ700 SRM.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION FOUND ON GUSSET AT FS 319.70 AND STRINGER 20R. C-CHECK RO 11/11/2020. CORROSION FOUND TO BE OUT OF LIMITS, PER CRJ700 SRM. REMOVED AND INSTALLED NEW GUSSET AT FS 319 STGR 20R, REF DWG CRJ700 SRM.