What was found
CORROSION ON ATTACHING ANGLE TO STGR 19L AND FRAME FS 295.00, MARKED. C-CHECK RO 12/14/2020. REMOVED AND INSTALLED "NEW" STRINGER CLEAT LOCATED ON STGR 19L AT FS 295, AS REQUIRED REF CRJ700 SRM AND DWG. SEE CONTINUE CARD FOR DETAILS.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION ON ATTACHING ANGLE TO STGR 19L AND FRAME FS 295.00, MARKED. C-CHECK RO 12/14/2020. REMOVED AND INSTALLED "NEW" STRINGER CLEAT LOCATED ON STGR 19L AT FS 295, AS REQUIRED REF CRJ700 SRM AND DWG. SEE CONTINUE CARD FOR DETAILS.