What was found
CORROSION ON RBL 9 FLOOR BEAM BETWEEN FS 439 AND FS 449 ON INBOARD FLANGE, MARKED. C-CHECK RO 12/20/2020. REMOVED CORROSION ON FLOOR BEAM INBOARD FLANGE FROM FS 439 TO FS 449, REF CRJ200 SRM 2.85"L X 0.67"W X 0.011"/0.007"/0.006"D. ORIGINAL MATERIAL THICKNESS IS 0.060", REF CRJ200 SRM AND STANDARDS MANUAL, LOWEST REMAINING THICKNESS IS 0.049" FOR A LOSS OF 0.011". FOUND TO BE OUT OF ALLOWABLE LIMIT OF 0.005" MAX MATERIAL REMOVAL, REF BOMBARDIER REO. COMPLIED WITH MHIRJ REO.