What was found
AFT WET AREA, CORROSION FOUND ON OUTBOARD RT GUSSET PLATE AT FR 90, AS MARKED. C-CHECK RO 12/27/2020. REMOVED AND REPLACED AFT WET AREA OUTBOARD RT GUSSET PLATE AT FR 90. RESTORED SURFACE PROTECTION REF SRM AND CPM.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFT WET AREA, CORROSION FOUND ON OUTBOARD RT GUSSET PLATE AT FR 90, AS MARKED. C-CHECK RO 12/27/2020. REMOVED AND REPLACED AFT WET AREA OUTBOARD RT GUSSET PLATE AT FR 90. RESTORED SURFACE PROTECTION REF SRM AND CPM.