What was found
STRINGER, STGR 26LT FROM FS 1098 THROUGH FS 985 HAS CORROSION, MARKED. C-CHECK RO 1/5/2021. REMOVED CORROSION FROM STRG 26L FROM FS 985.00 TO FS 1098.20. FOUND OUT OF LIMITS, DUE TO NO DAMAGE ALLOWED ON LOWER ATTACHING FLANGE, REF. CRJ700 SRM 53-61-03-101-003-A01. REMOVED AND INSTALLED NEW STRG 26L FROM FS 985.00 TO FS 1098.20, REF. MHIRJ REO 670-53-61-1779 REV -, DATED 2020-12-03, BOMBARDIER DWG MM670-35007 REV W AND CRJ700 SRM 53-00-03-201-001-A01. SEE CONTINUE CARD FOR MAINTENANCE PERFORMED. COMPLIED WITH SKYWEST TASK CARD 51-900-1002-SKY. LEAK CHECK GOOD.