Service difficulty report · Doubler · Cndair CL6002C10

Difficulty date
November 27, 2020
Submitted
February 8, 2021
Operation
Air carrier
Aircraft
N716EV
Make and model
Cndair CL6002C10
Aircraft serial
10084
Aircraft time
26,754 cycles
Part
Doubler
Condition
Corroded
Location
Drain Mast
Stage of operation
IN
How discovered
9
Nature of condition
O
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

*CORROSION ON DRAIN MAST INTERNAL PLATE/DOUBLER BETWEEN FS 1031.00 €“ 1047.00, RH OF STGR 27 (C-CHECK) RO 2/5/2021 REMOVED AND REPLACED DAMAGED AFT DRAIN MAST INTERNAL DOUBLER BETWEEN FS1031.00-1047.00 WITH NEW INTERNAL DOUBLER PN MM670-43255-001 IAW CRJ 700 SRM 51-42-06-001-001-A01. / COMPLIED WITH 51-900-1002-SKY PRESSURE CHECK GOOD.