What was found
CORROSION NOTED ON STRINGER 22L BETWEEN STATION 1015-1031 (C-CHECK RO 7/7/2021) COMPLIED WITH DOUBLER REPAIR AS PER CRJ 900 SRM 53-00-01-201-001-A03. SEE CONTINUE CARD FOR DETAILS, M337 AND TASK CARD 51-900-1002-SKY COMPLIED WITH.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION NOTED ON STRINGER 22L BETWEEN STATION 1015-1031 (C-CHECK RO 7/7/2021) COMPLIED WITH DOUBLER REPAIR AS PER CRJ 900 SRM 53-00-01-201-001-A03. SEE CONTINUE CARD FOR DETAILS, M337 AND TASK CARD 51-900-1002-SKY COMPLIED WITH.