As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
LH PRESSURE FLOOR SILL IS CORRODED AROUND FASTENER HOLES BETWEEN F.S. 513.00 AND F.S. 529.00. (C-CHECK RO 7/24/2021) REPAIRED LH PRESSURE FLOOR SILL BETWEEN FS513 AND FS529 IAW BOMBARDIER REO 601R-53-41-666 REV-C DATE 2012-11-06. & SKY CARD 51-900-1003-SKY NO WEIGHT CHANGE FORM 337 IS ATTACHED REFERENCE CONTINUATION CARD FOR WORK PERFORMED.