Service difficulty report · Floor Support · Cndair CL6002D24
FAA SDR system
- Difficulty date
- May 22, 2021
- Submitted
- August 2, 2021
- Operation
- Air carrier
- Make and model
- Cndair CL6002D24
- Aircraft serial
- 15070
- Aircraft time
- 37,109 hours, 23,528 cycles
- Part
- Floor Support
- Condition
- Corroded
- Location
- Zone 200
- Stage of operation
- IN
- How discovered
- 9
- Nature of condition
- O
- Precautionary procedure
- K
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
* CORROSION ON L/H FLOOR SILL BRACKET 3 PLACES UNDER FWD OVERWING EMER DOOR (C-CHECK RO 7/28/2021) REPAIRED SILL BRACKET ON LH PRESSURE FLOOR SILL, BELOW FWD EMER EXIT PER SRM 51-21-06-001-001-A01 & REO 690-53-41-270 REV --, DATED 2021-06-13. SEE CONTINUATION CARD FOR DETAILS. CHECKS GOOD. COMPLIED WITH TASK CARD 51-900-1002-SKY.