As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
SERVICES DOOR SURROUND STRUCTURE HAS A SPOT OF CORROSION FWD SIDE AT APPROXIMATE FLOOR LEVEL FS319.70 (C-CHECK RO 8/18/2021) REMOVED ATTACHING ANGLE (FITTING) P/N SH670-31990-1 AT APPROX FS 319.00 AND INSTALLED A NEW SERVICIABLE UNIT REF. CRJ700 SRM 51-42-21-001-001-A01 & DRAWING SH670-31950 REV. Y. COMPLIED WITH SKYWEST TASK CARD 51-900-1002-SKY