What was found
CIRCUMFERENTIAL JOINT BETWEEN FS. 280.00 TO 282.86 AND STRINGER 26LH TO 26RH IS CORRODED. (C-CHECK RO 8/19/2021) COMPLIED WITH DISPOSITION FOR BLENDED CORROSION DAMAGE TO FS280.00 BUTTSTRAP BETWEEN STR26L AND STR26R IAW MHIRJ REO 670-53-21-2014 REV.-- DATED 8/6/21. IAW CRJ700 SRM 51-42-06,51-21-06,51-25-06,51-25-16,51-21-11,51-23-00,51-42-00. CRJ700 NDTM 51-20-006. / STS-6796 CAL DATE 090921.PRESSURIZATION CHECK TO BE PERFORMED ON CAMP# 23231493 ITEM#1. SEE ATTACHED CONTINUE CARD FOR ANY ADDITIONAL INSTALLS/OPERATIONAL CHECKS.