As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FLOOR BEAM AT LBL27 CORRODED IN MULTIPLE SPOTS FROM F.S. 1015.00 TO F.S. 1047.00 (C-CHECK) RO 3/10/2021 REPAIRED CORRODED SPOTS ON FLOOR BEAM AT LBL27 FROM F.S. 1015.00 TO F.S. 1047.00 IAW MHIRJ REO 670-53-61-1817 REV - - DATED 2021-01-26. COMPLIED WITH TASK CARD 51-900-1002-SKY, REF ATTACHED M-337 FOR CHANGES TO WEIGHT AND BALANCE.