As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
* LH FLOOR SILL AT APPROXIMATELY FS985-FS1000 IS CORRODED (C-CHECK RO 4/4/2021) BLENDED THE CORRIOSION ON THE LH FLOOR SILL AT APPROX. FS.985-FS.1000 REF CRJ 700 SRM 51-21-06-001-001-A01 FOUND TO BE OUT OF LIMITS DUE TO NO ALLOWABLE DAMAGE REF CRJ 700 SRM 53-61-23-001-001-A01 AND CRJ 700 SRM 53-61-23-01-001-A01. RECEIVED AND COMPLIED WITH ALL APPLICABLE STEPS OF REO 670-53-61-1845 REV -- DATED 2021-03-12. WITHIN LIMITS. SEE CONTINUATION FOR FURTHER DETAILS.