What was found
RBL 9 BETWEEN F.S. 856.00 (SECTION AFT OF JOINT) AND F.S. 879.00 IS CORRODED BEYOND LIMITS AND REQUIRES REPAIR. (C-CHECK RO 4/22/2021) COMPLIED WITH RBL9 FLOOR BEAM FLANGE REPAIR BETWEEN FS863.00-FS879.00 REF-CRJ-700 SRM 53-00-41-201-001 A01 AND COMPLIED WITH REO 670-53-51-209 REV -- DATED 2021-03-24 AT RBL9 FS856 APPROX WITH THE BLEND OUT AREA IS WITHIN LIMITS. / COMPLIED WITH TASK 51-900-1002-SKY