As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
LH FS 559 STRAP UNDER FLOOR PANEL LBL 27 TO 40 APPROX HAS CORROSION AS FLAGGED. (C-CHECK RO 5/20/2021) REMOVED AND REPLACED STRAP P/N 601R31025-29 REF CRJ 200 SRM 51-42-06 , 51-42-15 AND DRAWING 601R31025 REV N. SEE CONTINUATION CARD FOR DETAILS. PRESSURE CHECK GOOD. COMPLIED WITH TASK CARD 51-900-1003-SKY.