As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
RH FS 559 STRAP UNDER FLOOR PANEL RBL 27 TO 40 APPROX HAS CORROSION AS FLAGGED. (C-CHECK RO 5/20/2021) REMOVED AND INSTALLED NEW STRAP AT FS559 RBL27 TO RBL40 REF DWG 601R31025 REV N, CRJ200 SRM 51-42-06 AND CRJ200 SRM 51-45-00. PRESSURE CHECK GOOD. COMPLIED WITH TASK CARD 51-900-1003-SKY.