As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
SUSPECTED CRACK ON LBL9.00 PRESSURE FLOOR-SUPPORT BEAM TIE-CLIP TO CROSS-MEMBER AT FS484.00 (MARKED) (C-CHECK RO 5/20/2021) REMOVED AND INSTALLED NEW CLIP AT FS484 ON LBL9 REF DWG 601R31171 REV-B AND REO 601R-53-41-2908 REV--, DATED 2021-04-23. COMPLIED WITH TASK CARD 51-900-1003-SKY.