What was found
CORROSION DETECTED ON INTERCOSTAL ATTACHED TO STGR (22R) BETWEEN F.S. 897.00 AND 913.00. (C-CHECK RO 7/7/2021) EVALUATED CORROSION ON INTERCOSTAL ATTACHED TO STGR 22R BETWEEN FS 897.00 AND FS 913.00. CORROSION FOUND TO BE OUT OF ALLOWABLE LIMITS. REF CRJ-900 SRM 53-00-00-101-001-A01. REMOVED DAMAGED INTERCOSTAL AND INSTALLED NEW FABRICATED INTERCOSTAL P/N SH690-37104-2. REF CRJ-900 SRM 51-42-06-001-001-A01 AND DWG SH690-37060 REV AC DATED 2018-08-06. COMPLIED WITH ST 51-900-1002-SKY (CL600-2D24) STRUCTURAL MAJOR REPAIR (RII)