What was found
*CORROSION ON STGR 26L BETWEEN FS 310.00 - 295.00 (C-CHECK RO 8/18/2021) BLENDED OUT CORROSION ON STGR 26L BETWEEN F.S. 295.00 AND F.S. 310.00, BLENDED OUT CORROSION ON STGR 26L BETWEEN F.S. 295 AND 310.0 FOUND OUT OF LIMITS, MEASURED REMAINING MATERIAL THICKNESS .047'', NOMINAL THICKNESS .063'', MATERIAL LOSS .016'', LOSS EXCEEDS 10% OF PART NOMINAL THICKNESS, REF CRJ 900 SRM 53-21-03-101-001-A04, CRJ 900 SRM 53-32-59-001-001-A01. STGR 26L REPLACED BETWEEN F.S. 280.0 - F.S. 333.00 ON JOB 91506794 OP 160 CAMP #22949718, SKY CARD COMPLIANCE FOR A MAJOR REPAIR, FORM M-337 AND PRESSURE LEAK CHECK OF STGR 26L ACCOMPLISHED ON THE AFORE MENTIONED CAMP.