As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
* FLOOR BEAM ATTACH "T" BRACKET AT THE FORWARD CORNER OF THE SERVICE DOOR CUTOUT IS CORRODED. (C-CHECK RO 9-30-21) FOUND T BRACKET AT FWD CORNER OF SERVICE DOOR CUTOUT OUT OF LIMITS REF CRJ 200 SRM 53-00-00 AND REPLACED WITH A NEW T BRACKET REF CRJ 200 SRM 51-42-21 AND DRAWING 601R38303 REV AR.COMPLIED WITH TASK CARD 51-900-1003-SKY