What was found
*MULTIPLE AREAS OF CORROSION ON EXTERNAL FUSELAGE SKIN, MATING SURFACE FOR PANEL 196DR BETWEEN FS 847.00 €“ 1015.00, STGR 18R - 27 (C-CHECK RO 9/27/2021) REMOVED MULTIPLE AREAS OF CORROSION ON EXTERNAL FUSELAGE SKIN, MATING SURFACE FOR PANEL 196DR BETWEEN FS 847.00 €“ 1015.00, STGR 18R - 27 WITHIN LIMITS. RESTORED FINISH. RE-APPLIED SEALANT PAD. REF REO 670-53-00-663 REV -- DATED 2021-07-07