What was found
*OVERWING FLOOR SUPPORT BEAM AT FS460 BELOW PRESSURE FLOOR HAS A MIGRATING SHIM AT RH PAD BETWEEN RBL18 AND RBL27. (C-CHECK RO 10/4/2021) REPAIRED MIGRATING SHIM PER REO 601R-53-41-2954 (REV --) DATED 2021-08-25 AND REO 601R-53-41-100 (REV NC) DATED 2002-08-08. COMPLETED SKYWEST TASK CARD 51-900-1003-SKY. / STEPS 1 AND 2 OF GENERIC REO 601R-53-41-100 (REV NC) DATED 2002-08-08 MUST BE RE-ACCOMPLISHED AFTER 3000 FLIGHT HOURS FROM THE TIME OF INCORPORATION OF THIS REO. NO WEIGHT AND BALANCE CHANGE FROM REPAIR.