What was found
FIRST OFFICER WINDSHIELD CONTAINS MINOR CRACKS IN THE (STRUCTURAL) GLASS PLIES ALL AROUND EDGES. (C-CHECK RO 10/9/2021) REMOVED OF THE FIRST OFFICER WINDSHIELD PER AMM TASK 56-11-01-000-801 (CONFIG A01) / REMOVAL OF THE WINDSHIELD SIDE STRAP AMM TASK 56-10-05-000-801 (CONFIG A01) / INSTALLED A NEW FIRST OFFICER WINDSHIELD PER CRJ 700 AMM 56-11-01-400-801 (CONFIG A01). / RE-INSTALLED THE WINDSHIELD SIDE STRAP PER CRJ 700 AMM 56-10-05-400-801 (CONFIG A01 / NO DISCREPANCIES NOTED. / PLEASE REFERENCE CAMP 23165335 FORTHE PRESSURIZATION LEAK CHECK.