What was found
CORROSION ON FRAME AT FS 409+16 AT STR 27 (FILED CLOSED) CORROSION TO BE FOUND OUT OF LIMITS. REPAIRED FRAME AT FS 409+16 STR 25L TO STR 26R WITH FRAME SPLICE REPAIR IAW CRJ200 SRM 53-00-15 SRM 51-23-00 SRM 51-25-00 SRM 51-42-06 SRM 51-42-21 / CALIBRATED TOOLS USED: / OLYMPUS 600 NORTEC AV8958 CAL DUE SEP2021 / NEGLIGIBLE WEIGHT CHANGE NOTED. / WEIGHT CHANGE NEGIGIBLE. PRESSURE CHECK GOOD. COMPLIED WITH 51-900-1003-SKY