As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
F/S 314 & F/S 343 LBL 36 WL 73.50 CORROSION ON 2 EACH FLOOR SUPPORT FITTINGS (PAX) DOOR AREA (FILED CLOSED) REMOVED AND REPLACED (2) FLOOR SUPPORT FITTINGS ON PAX DOOR SILL IAW CRJ200 SRM 51-24-00 SRM 51-40-00 SRM 51-25-00 SRM 51-23-00 AND SRM 51-42-10 / CALIBRATED TOOLS USED: / PIN MICROMETER AV1070 CAL DUE FEB 2022