What was found
CREASE IN FUSELAGE SKIN UNDER SERVICE DOOR AT FS 333.00 BETWEEN STGR21R AND STRGR22R . NEEDS TO BE EVALUATED . (C-CHECK RO 1/13/2022) PERFORMED REPAIR ON FUSELAGE SKIN CREASE UNDER SERVICE DOOR AT FUSELAGE STATION FS 333.00 BETWEEN STRINGER STGR21R AND STGR 22R PER REPAIR ENGINEERING ORDER (REO) 670-53-21-2176 REV-- DATED 2021-11-10. PLEASE REFER TO CONTINUATION CARD FOR REPAIR DISPOSITIONS AND CORRECTIVE ACTIONS. NO FURTHER ACTION REQUIRED.