What was found
FOUND EXFOLIATED L/H MLG ELECTRICAL/HYDRAULIC PROTECTIVE COVER ANGLE (C CHECK RO 1/16/2022) REMOVED ANGLE IAW CRJ700 SRM 51-42-21-001-001-A01, INSTALLED NEW ANGLE P/N CC670-10338-1 IAW CRJ700 SRM 51-42-21-001-001-A01, 51-23-00-001-001-A01, DWG CC670-10320 REV-F, LEAK CHECK GOOD, NO DEFECTS NOTED / COMPLIED WITH TASK CARD 51-900-1002-SKY