As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
*FS333.00 STGR 21LH SPLICE HAS SEVERAL AREAS OF CORROSION (MARKED) (C-CHECK RO 1/19/2022) REMOVED AND REPLACED STGR 21L SPLICE AT FS333.00 REF CRJ900 SRM 51-42-06-001-001-A01 AND DWG SH670-32420 REV E AND COMPLIED WITH SKYWEST TASK CARD 51-900-1002-SKY. LEAK CHECK GOOD