As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
RH FLOOR SILL HAS MULTIPLE SPOTS OF CORROSION FROM FS.424.00 TO FS.473.15. (C CHECK RO 2-11-2022) COMPLIED WITH BOMBARDIER REO 601R-53-41-666 REV-C DATED: 2012-11-06. COMPLIED WITH SKY CARD 51-900-1003-SKY AND 337 COMPLETED. WEIGHT AND BALANCE NOT EFFECTED. REFERENCE CONTINUE CARD FOR WORK PERFORMED.