As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
L/H PRESSURE FLOOR SIL HAS ELONGATED NUTPLATE HOLE AT FS 424. (C CHECK RO 2-11-2022) COMPLIED WITH REPAIR OF L/H PRESSURE FLOOR SIL IAW MHIRJ REO 601R-53-41-2995 REV.-- DATED 2022-01-10. ATTACHED COMPLETED TASK CARD 51-900-1003-SKY AND COMPLETED FORM 337. NO WEIGHT CHANGE.