*ATTACH ANGLE IN L/H INBD WING DRY-BAY HAS AREA OF CORROSION. LOCATION IS IN THE WHEEL WELL OTBD FWD AREA. (C-CHECK RO 2/16/2022) REMOVED AND REPLACED ATTACH ANGLE IN LH INBD WING DRY BAY. REF CRJ-900 SRM 51-42-21-001-001-A01 AND CRJ 900 SRM 51-42-06-001-001-A01, DWG CC670-10320 REV -E AND MHIRJ REO 690-57-22-063 REV -- DATED 2021-12-17. COMPLIED WITH SKYWEST TASKCARD 51-900-1002-SKY. SEE CONTINUATION CARD FOR DETAILS.