As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
*MAIN AVIONICS BAY STR 26R CORRODED BETWEEN FS333.00 AND FS364.00. (C-CHECK RO 2/16/2022) REMOVED AND INSTALLED NEW STR 26R FROM FS333.00 TO FS364.00. REF DWG SH690-31350 REV M AND CRJ-900 SRM 51-42-06-001-001-A01.. PRESSURE CHECK GOOD. COMPLIED WITH SKYWEST TASK CARD 51-900-1002-SKY / SEE CONTINUATION CARD FOR DETAILS OF WORK PERFORMED.