What was found
MAIN AVIONICS BAY STR 24R SPLICE AT FS333.00 CORRODED (C-CHECK RO 2/16/2022) REMOVED DAMAGE AND EVALUATED REPAIR. REPAIR FOUND TO BE OUT OF LIMITS. REMOVED AND REPLACED DAMAGED STRINGER. REF. CRJ 900 SRM 51-42-06-001-001-A01 AND DWG SH670-32420 REV E,. PRESSURE CHECK GOOD. COMPLIED WITH SKYWEST TASK CARD 51-900-1002-SKY / SEE CONTINUATION CARD FOR DETAILS OF WORK PERFORMED.