What was found
*MULTIPLE AREAS OF CORROSION ON FRAME FS 310.00 BETWEEN STGR 25L €“ 25R (C CHECK RO 02/22/2022) REMOVED AND REPLACED CORROSION AT FS310.00 BETWEEN STR 25R AND STR 25L IAW CRJ700 SRM 51-21-06-001-001-A01 AND EVALUATED FRAME FS 310.00 BETWEEN STR 25L AND STR 25R,ORIGINAL THICKNESS 0.050 IN. IAW CRJ700 SRM 53-21-06-001-002-A01, MATERIAL LOSS 0.008 IN. REMAINING MATERIAL THICKNESS 0.042 IN. FRAME FOUND TO BE WITHIN LIMITS. IAW CRJ700 SRM 53-00-06-201-005-A01