What was found
L/H SIDE FUSELAGE FS453, BETWEEN STR14L & 15L DENT; MEASURE AT 3"X 4" .010" DEPTH; NO ALLOWABLE DAMAGE IN AREA. (C-CHECK RO 3/10/2022) PERFORMED REPAIR ON FRAME AT FS453 BETWEEN STGR14L & 15L PER MHIRJ REO 670-53-21-2198 REV. -- DATED: 2021-12-21 AND REO 670-51-00-085 REV. -A DATE: 2017-08-23. REFER TO CONTINUATION CARD (2) FOR DISPOSITION AND CORRECTIVE ACTION. NO FURTHER ACTION REQUIRED AT THIS TIME.