What was found
* LH SLAT TRACK 2-1 SHOWING MULTIPLE FLAT SPOTS ON THE FRONT SIDE OF TRACK (AREA MARKED) (C-CHECK RO 8/14/2022) REMOVED DAMAGE FROM L/H SLAT TRACK 2-1 PER CRJ 700 SRM 51-12-00 TASK 51-12-00-001-001-A01. O/B BLEND MEASURES 5.00" X .400" ORIGINAL MATERIAL THICKNESS @ .230"/.270€? REMAINING MATERIAL THICKNESS @ .258" MATERIAL LOSS OF .001" @ BLEND LOCATION. I/B BLEND MEASURES 5.10" X .400" ORIGINAL MATERIAL THICKNESS @ .230"/.270" REMAINING MATERIAL THICKNESS @ .256" MATERIAL LOSS OF .001" @ BLEND LOCATION. REF DWG CC670-12042 REV C DATED 12/16/1999 TUC8914 CAL DUE 31-AUG-22. / COMPLIED WITH ALL STEPS OF MHIRJ REO 670-57-42-1360 REV-- DATED 2022-07-08. / OPS/RIG CHECK FOUND GOOD AT THIS TIME. / COMPLIED WITH SKYWEST TASK CARD 51-900-1002-SKY.