What was found
DENT OIL CANNING ON RH FUSELAGE, FWD. OF FRAME 94 AND ABOVE STRINGER 23R, AT REAR FUSELAGE ACCESS DOOR. (C CHECK RO 01/28/2022) REPAIRED DENT ON RH FUSELAGE, FWD. OF FRAME 94 AND ABOVE STRINGER 23R, AT REAR FUSELAGE ACCESS DOOR. REF SRM 53-30-01/REPAIR12P. REPAIR INSPECTION REQUIRMENTS : DET EXTERNAL SIDE INSPETION THRESHOLD 20,000 FC OR 26,600 FH WHICHEVER OCCURS FIRST, INSPECTION INTERVAL 10,000 FC OR 13,300 FH WHICHEVER OCCURS FIRST.