*CORROSION FOUND ON FLOOR BEAM SUPPORT AT FS985.00 AT APPROX LBL42 (MARKED) (C-CHECK RO 2/16/2022) REPLACED FLOOR BEAM SUPPORT AT FS985.00 AT APPROX. LBL 42 REF DWG MM670-35041 REV. Y AND CRJ900 SRM 51-42-06-001-001-A01. COMPLIED WITH 51-900-1002-SKY.