As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
*CORROSION FOUND IN SEVERAL SPOTS ON R/H FLOORSILL BETWEEN FS1069.75 AND FS1088.00 (MARKED) (C-CHECK RO 2/16/2022) PERFORMED REO REPAIR OF FLOOR SILL BETWEEN FS 1069.75 AND FS 1088.00 R/H SIDE. FLOOR SILL REPAIRED PER REO 690-53-61-1056 REV -- DATED 2022-01-14 / COMPLIED WITH SKYWEST TASK CARD 51-900-1002-SKY / SEE CONTINUATION CARD FOR DETAILS OF WORK PERFORMED