What was found
RH WINDSHIELD POST APPEARS CRACKED RADIATING FORWARD FROM UPPER BARREL NUT HOLE. (C CHECK RO 02/22/2022) C/W NDT INSP REF CRJ-700 NDTM PT1 51-20-006-250-A01. CRACK NOTED TUC9452 CAL DUE 31 AUG 2022. SEE ATTACHED NDT -9 REPORT. / REMOVED AND REPLACED BEAM WITH REPLACEMENT FASTENERS REF CRJ700 SRM 51-42-21-001-001-A01 AND DRW. 601R33007 REV U. / NO LEAKS NOTED. COMPLIED WITH 51-900-1002-SKY